MYLEX CORPORATION
DAC960SU, DAC 960SUI
Card Type |
Hard drive controller card |
Maximum Onboard Memory |
Unidentified |
Hard Drives supported |
Up to 15 SCSI devices |
Floppy drives supported |
None |
CONNECTIONS | |||
Function |
Location |
Function |
Location |
Unidentified connector |
CN1 |
AEMI (Array Enclosure Management Interface) port |
J5 |
Unidentified connector |
CN2 |
FAST/WIDE Ultra-SCSI connector drive channel 0 |
J8 |
Unidentified connector |
CN3 |
FAST/WIDE Ultra-SCSI connector drive channel 1 |
J9 |
Edge connector (connects to P1) |
CN4 |
Power connector |
J10 |
Fault indication, drive channel 0 |
J1 |
FAST/WIDE SCSI connector host channel 0 |
J11 |
Fault indication, drive channel 1 |
J2 |
Power connector |
J12 |
Serial port |
J3 |
Edge connector (connects to CN4) |
P1 |
Reserved (do not use) |
J4 |
USER CONFIGURABLE SETTINGS | |||
Function |
Label |
Position | |
» |
Factory configured - do not alter |
JP6/E |
Open |
» |
Serial port protocol SLP1 |
JP6/F |
Open |
Serial port protocol VT100 |
JP6/F |
Closed | |
» |
Factory configured - do not alter |
JP6/G |
Closed |
» |
Factory configured - do not alter |
JP6/H |
Closed |
» |
Termination disk channel 0 enabled |
JP13/A |
Closed |
Termination disk channel 0 disabled |
JP13/A |
Open | |
» |
Termination disk channel 1 enabled |
JP13/B |
Closed |
Termination disk channel 1 disabled |
JP13/B |
Open | |
» |
Termination host channel 0 enabled |
JP13/C |
Closed |
Termination host channel 0 disabled |
JP13/C |
Open | |
» |
Factory configured - do not alter |
JP13/D |
Open |
» |
Factory configured - do not alter |
JP13/E |
Open |
SCSI ID SELECTION | ||||
SCSI ID |
JP6/A |
JP6/B |
JP6/C |
JP6/D |
0 |
Open |
Open |
Open |
Open |
1 |
Closed |
Open |
Open |
Open |
2 |
Open |
Closed |
Open |
Open |
3 |
Closed |
Closed |
Open |
Open |
4 |
Open |
Open |
Closed |
Open |
5 |
Closed |
Open |
Closed |
Open |
6 |
Open |
Closed |
Closed |
Open |
7 |
Closed |
Closed |
Closed |
Open |
8 |
Open |
Open |
Open |
Closed |
9 |
Closed |
Open |
Open |
Closed |
10 |
Open |
Closed |
Open |
Closed |
11 |
Closed |
Closed |
Open |
Closed |
12 |
Open |
Open |
Closed |
Closed |
13 |
Closed |
Open |
Closed |
Closed |
14 |
Open |
Closed |
Closed |
Closed |
15 |
Closed |
Closed |
Closed |
Closed |
DRAM CONFIGURATION |
Note: The DRAM configuration is unidentified. |
MISCELLANEOUS TECHNICAL NOTES |
The functions of front control panel switches of this housing are unidentified. Card configuration for the DAC9600SU and DAC9600SUI is identical except for the DAC9600SUI comes with the cards contained in a 5.25 inch full height drive housing. |