INDUSTRIAL COMPUTER SOURCE

AOB6-P

Card Type

Analog to digital timing converter, Digital I/O card

I/O Options

Serial port

Data Bus

8-bit ISA

Card Size

Full-length

CONNECTIONS

Function

Label

DB-37 connector

CN1

VOLTAGE RANGE SETTINGS

Function: Voltage Range

SW0/1

SW0/2

SW0/3

SW0/4

SW0/5

SW0/6

0V to 5V

On

Off

Off

Off

On

Off

0V to 10V

Off

On

Off

Off

On

Off

-2.5V to +2.5V

On

Off

Off

On

On

Off

-5V to +5V

On

Off

Off

On

Off

Off

-10V to +10V

Off

On

Off

On

Off

Off

VOLTAGE RANGE SETTINGS

Function: Voltage Range

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

SW1/6

0V to 5V

On

Off

Off

Off

On

Off

0V to 10V

Off

On

Off

Off

On

Off

-2.5V to +2.5V

On

Off

Off

On

On

Off

-5V to +5V

On

Off

Off

On

Off

Off

-10V to +10V

Off

On

Off

On

Off

Off

VOLTAGE RANGE SETTINGS

Function: Voltage Range

SW2/1

SW2/2

SW2/3

SW2/4

SW2/5

SW2/6

0V to 5V

On

Off

Off

Off

On

Off

0V to 10V

Off

On

Off

Off

On

Off

-2.5V to +2.5V

On

Off

Off

On

On

Off

-5V to +5V

On

Off

Off

On

Off

Off

-10V to +10V

Off

On

Off

On

Off

Off

VOLTAGE RANGE SETTINGS

Function: Voltage Range

SW3/1

SW3/2

SW3/3

SW3/4

SW3/5

SW3/6

0V to 5V

On

Off

Off

Off

On

Off

0V to 10V

Off

On

Off

Off

On

Off

-2.5V to +2.5V

On

Off

Off

On

On

Off

-5V to +5V

On

Off

Off

On

Off

Off

-10V to +10V

Off

On

Off

On

Off

Off

VOLTAGE RANGE SETTINGS

Function: Voltage Range

SW4/1

SW4/2

SW4/3

SW4/4

SW4/5

SW4/6

0V to 5V

On

Off

Off

Off

On

Off

0V to 10V

Off

On

Off

Off

On

Off

-2.5V to +2.5V

On

Off

Off

On

On

Off

-5V to +5V

On

Off

Off

On

Off

Off

-10V to +10V

Off

On

Off

On

Off

Off

VOLTAGE RANGE SETTINGS

Function: Voltage Range

SW5/1

SW5/2

SW5/3

SW5/4

SW5/5

SW5/6

0V to 5V

On

Off

Off

Off

On

Off

0V to 10V

Off

On

Off

Off

On

Off

-2.5V to +2.5V

On

Off

Off

On

On

Off

-5V to +5V

On

Off

Off

On

Off

Off

-10V to +10V

Off

On

Off

On

Off

Off

CURRENT RANGE SETTINGS

Function: Current Range

SW0/1

SW0/2

SW0/3

SW0/4

SW0/5

SW0/6

1 - 5 mA

On

Off

On

Off

On

Off

4 - 20 mA

On

Off

On

Off

On

On

0 - 50 mA*

On

Off

Off

Off

On

On

* Signifies option requiring addition of one 167 ohm resistor per channel

CURRENT RANGE SETTINGS

Function: Current Range

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

SW1/6

1 - 5 mA

On

Off

On

Off

On

Off

4 - 20 mA

On

Off

On

Off

On

On

0 - 50 mA*

On

Off

Off

Off

On

On

* Signifies option requiring addition of one 167 ohm resistor per channel

CURRENT RANGE SETTINGS

Function: Current Range

SW2/1

SW2/2

SW2/3

SW2/4

SW2/5

SW2/6

1 - 5 mA

On

Off

On

Off

On

Off

4 - 20 mA

On

Off

On

Off

On

On

0 - 50 mA*

On

Off

Off

Off

On

On

* Signifies option requiring addition of one 167 ohm resistor per channel

CURRENT RANGE SETTINGS

Function: Current Range

SW3/1

SW3/2

SW3/3

SW3/4

SW3/5

SW3/6

1 - 5 mA

On

Off

On

Off

On

Off

4 - 20 mA

On

Off

On

Off

On

On

0 - 50 mA*

On

Off

Off

Off

On

On

* Signifies option requiring addition of one 167 ohm resistor per channel

CURRENT RANGE SETTINGS

Function: Current Range

SW4/1

SW4/2

SW4/3

SW4/4

SW4/5

SW4/6

1 - 5 mA

On

Off

On

Off

On

Off

4 - 20 mA

On

Off

On

Off

On

On

0 - 50 mA*

On

Off

Off

Off

On

On

* Signifies option requiring addition of one 167 ohm resistor per channel

CURRENT RANGE SETTINGS

Function: Current Range

SW5/1

SW5/2

SW5/3

SW5/4

SW5/5

SW5/6

1 - 5 mA

On

Off

On

Off

On

Off

4 - 20 mA

On

Off

On

Off

On

On

0 - 50 mA*

On

Off

Off

Off

On

On

* Signifies option requiring addition of one 167 ohm resistor per channel

ANALOG-OUTPUT UPDATE SETTINGS

Channels

SW6/1

SW6/2

SW6/3

SW6/4

SW6/5

SW6/6

A0, A1

On

Off

Off

On

Off

Off

A2, A3

Off

On

Off

Off

On

Off

A4, A5

Off

Off

On

Off

Off

On

Simultaneous

On

On

On

Off

Off

Off

External

Off

Off

Off

On

On

On

None

Off

Off

Off

Off

Off

Off

BASE I/O ADDRESS SELECTION

Setting

SW7/1

SW7/2

SW7/3

SW7/4

SW7/5

SW7/6

000h

On

On

On

On

On

On

010h

On

On

On

On

On

Off

030h

On

On

On

On

Off

Off

200h

Off

On

On

On

On

On

2D0h

Off

On

Off

Off

On

Off

300h

Off

Off

On

On

On

On

380h

Off

Off

Off

On

On

On

3C0h

Off

Off

Off

Off

On

On

3E0h

Off

Off

Off

Off

Off

On

3F0h

Off

Off

Off

Off

Off

Off

Note:

A total of 64 base address settings are available. The switches are a binary representation of the decimal memory addresses. SW7/1 is the Most Significant Bit and switch SW7/6 is the Least Significant Bit. The switches have the following decimal values: SW7/1=512, SW7/2=256, SW7/3=128, SW7/4=64, SW7/5=32, SW7/6=16. Turn off the switches and add the values of the switches to obtain the correct memory address. (Off=1, On=0)